Facility | BL | X-ray Energy | Energy Resolution | Photon Flux | Beam Size at Sample | Diffractometer/Detector | Sample Conditions |
---|---|---|---|---|---|---|---|
AR (PF) | AR-NE3A | ||||||
SPring-8 | BL09XU | 9 ∼ 80kev | Note 1) | 1.4 ~ 1013 photons/s (@ 14.4 keV, 100 mA) (*1) | 2.7 mm(H) ~ 1.0 mm(V) | ƒÖ-2ƒÆ goniometer, Tangential bar-type goniometer, Avalanche photodiode detector, p-i-n photodiode detector, Scintillation detector, Ionization chamber | Cryostat, Room temperature controller |
BL11XU | 6 ∼ 70keV | Precision goniometer (Horizontal axis, driven by stepping motor, Resolution : 0.01 arcsec/pulse) | |||||
BL35XU | 1.5 meV resolution at 21.748 keV (Si (11 11 11)), 6 meV resolution at 15.816 keV (Si (888)) | ∼ ƒÓ100 ƒÊm (FWHM) | Eulerian Cradle (Huber 512.1) for IXS (Vertical or horizontal scattering plane) | Closed cycle He cryostat (~ 10 - 300 K), LN2 cryostat (~ 80 - 300 K), Furnace (~ 300 - 1000 K) |
Note 1: For detailed Energy Resolution and Photon Fluxe for individual nucleus, see web pages of the beamlines.